💰>>>>>>>> Make A Donation <<<<<<<<💰

Station-Drivers only receives 50% of advertising revenue and the rest from donations to finance the operation of S-D, I internally thank some who regularly give me €1, €2, €5, €10,..., to be able to continue. A big thank you to those who give me regularly like 😉: Filippo-F, Ansley-B, Thierry-L, Jesus-F, Petr-H, Dionysios-S, Andreas-M, Amrit-L, Adrianus-L, Yunlun-T, Marlon-B, ....
This allows me to continue my passion and be able to share it with you allFdrsoft 


Information! With the donations made, Station-Drivers will migrate to a new, more powerful server in early August 2024 to resolve the site's slowdown problems (J-12).

 

Aujourd'hui nous allons vous montrez comment mettre à jour votre Hub USB 3.0 intégrant un chipset Genesys Logic GL-3520

Le hub pour ce dossier et un modèle Winstar WS-UH3072 intégrant deux chipsets GL-3520 en version 9026 que nous allons mettre à jour vers la version 9030 qui est la dernière à ce jour. 

Pour commencer, télécharger le pack du firmware version 9030 (genesys_gl3520_fw9030_perso) puis décompresser le.

Lancez le fichier GLUSBFLT_SETUP_V2.04.exe qui est un filtre et permet la mise à jour (Attention certain port USB ne fonctionnerons plus le temps de la mise à jour). 

Ne pas redémarrer après l'installation des filtres puis lancez GL3520ISP.exe et cliquez sur " Update FW ".

Attention ! , Attendre la fin de la mise à jour qui dure a peu près 5Mn puis couper et rallumer l'alimentation du Hub et redémarrer votre ordinateur pour la prise en compte du nouveau firmware.

 

Pour vérifier si la mise à jour à réussi, relancer le fichier " GL3520ISP.exe " 

Voilà votre Hub USB 3.0 et maintenant à jour 

Voici la liste des firmwares disponibles: Version 4401, 9030, 9036

Release note

Firmware 9020

  • 1. Improve compatibility with Renesas202/FL1100 host
  • 2. Resolve ISP tool issues for SS_MaxPower/MaxPower/PowerGood
  • 3. Enabled SS Remote Wakeup
  • 4. Add an option for down-port power always on

Firmware 9021 

  • 1. Improve compatibility with FL1100 host and Macbook
  • 2. Fix MaxPower value issue for self/bus power
  • 3. Improve compatibility with charging applications
  • 4. Improve suspend current for USB2.0 Hub

  Firmware 9022

  • 1. Improve compatibility with FL1100 host
  • 2. Improve compatibility with charging applications
  • 3. Improve compatibility with LVS and Link tests

 Firmware 9023

  • 1. Improve compatibility with FL1100 host
  • 2. Improve compatibility with charging applications
  • 3. Improve compatibility with polyfuse
  • 4. Fix LED ON/OFF issue

 Firmware 9024

  • 1. Update suggested SR and JK values for Genesys evaluation board
  • 2. Improve compatibility with QC tool 

Firmware 9025

  • Improve the stability with CDP applications

 Firmware 9026

  • 1. Improve compatibility with power switch
  • 2. Improve stability with DCP applications

Firmware 9027

  • Improve compatibility with Macbook

Firmware 9028

  • Improve compatibility with Intel host

 Firmware 9029

  • 1. Improve compatibility with xHCI host
  • 2. Improve power consumption while configured

Firmware 9030 

  • 1. Fix SSC disabled issue in the compliance mode for FW9028/9029
  • 2. Improve compatibility under USB2.0 Hub with EHCI host 

Le site Station-Drivers ne peut en aucun cas être tenue pour responsable en cas de panne materiel !

Maj du 23/06/2014: Nouveau firmware Version 9036

Maj du 20/05/2017: Nouveau firmware Version 9223

Maj du 05/10/2016 Nouveau firmware Version 9224

 

No comments